Many of us who have been warmed up have heard about it, but we should not be very familiar with it because warming abroad has become more commonplace in China and it has not yet been a long time for us to enter China. Today, we will share some of the questions regarding electric heating installation. Knowledge, to what extent is the distance between the warm tubes. Then, please follow the footsteps of Xiao Bian together to understand the relevant content of the floor heating pipe spacing.
Floor heating pipe spacing:
Electric floor heating and floor heating have not been in China for a long time. People have not used it for the whole year. Therefore, many of our users are aware of some erroneous awareness about installation of floor heating. Many users believe that the distance between floor heating pipes should be The smaller the better, because it can completely save heat and save resources, and the family's expenses are reduced, but many people do not realize that this is not correct.
When we reduce the distance between the floor heating pipes, the ground heating loop will add a lot of turning points, and the thermal resistance will increase, and the construction difficulty will be greatly increased, and it is usually easy to cause the circulation to be unclear or partially If the place is overheated, the reduction in spacing will have a serious impact on the effectiveness of our floor heating function, and it will add unnecessary trouble to the future use process. Therefore, in order not to cause the above situation, we In the installation of floor heating pipes, reasonable installation should be carried out according to the correct design and the orientation of our house.
Well, the distance between floor heating pipes is the most appropriate. Generally, the best distance between warm pipes is 20, and geothermal construction is more popular in recent years. 50% of users will have to renew their new home decoration. The idea of ​​floor-heating installations occupies a very high proportion, so many geothermal companies produce, and geothermally installed studios are very particular about the fact that not everyone is competent. It needs to conduct a full study and study for us differently. The user studies different options and should have professional drawings when performing the construction.
Generally speaking, the precise measurement of the ruler is applied when geothermal is installed. The actual area of ​​the test house is not the construction area, and then the amount of the coffin to be used is calculated. The general production interval is between 10 and 30 centimeters. A large part of the user's paving distance is relatively suitable in 20, if it is on the ground floor or in the basement, it can be 15 cm, and it should avoid being too wide or too narrow. Otherwise, the ideal effect is difficult to achieve, so our users should realize that the spacing between the floor heating pipes is not as small as possible. When we install the floor heating pipe, the interval between them is 20 cm, and each square meter is approximately The floor heating pipe extends the rice pipe at 5, and it is not reasonable if the number of rice is over or under.
There are two types of floor heating pipes, one is a pipe diameter of 16, and the other is a pipe diameter of 20. The pipe spacing of these two types is certainly different. The pipe spacing is also different in various aspects, such as the spacing of pipes in general bathrooms. Between 100-120. The bedroom living room is between 200-250, 20 tubes because of diameter reasons so the tube spacing can not reach the distance of 16, so all aspects of data should be greater than 16 tube spacing of 20 or so, the above units are mm.
Floor heating pipe to distinguish authenticity:
First, look at the surface of the floor heating pipe. The surface of the floor pipe with good quality is relatively smooth and not concavo-convex, bubbles, obvious color difference and impurities, and the floor heating pipes all show the models, specifications and brands of floor heating pipes. The lettering on the warm floor pipe is relatively clear and does not easily fall off.
Second, to feel whether the pipe has a groove by hand, the quality of the pipe feels delicate, smooth, moderate hardness.
Third, compare the flexibility of the pipe with the thickness of the wall thickness, individual wall thickness of the warm pipe are marked as 2.0, some floor heating pipe is marked with a wall thickness of 2.0, but in fact the wall thickness can not reach, but the quality of a good floor heating pipe The wall thickness is able to reach the request and is the same as the callout. When you rely on a single pipe, you may be able to compare the two pipes to see which one has a thicker wall.
Fourth, to the detection part of the monitoring, to the detection part of the detection is the way to take a suspicion of the floor heating pipe, under individual circumstances, the floor heating company used floor heating pipe are qualified products, and a test report with the warranty pledge, simple pipe The quality test method may be performed with the naked eye, but the test of the function index can only be performed in the laboratory.
The above is related to the introduction of floor heating pipe spacing. If you want to know more related information, please pay more attention to this site, and we will provide you with more complete, more detailed and updated information information.