1, fire safety management system
First, fire safety management should implement a step-by-step fire safety responsibility system and post fire safety responsibility system, specify fire safety responsibilities for each level and post, and determine the fire safety responsible persons at all levels and positions. Do fire work in all departments and make sure that someone is responsible for management.
Second, a fire safety regular meeting system should be established, regular fire safety regular meetings should be held to deal with major issues involving fire safety, and research, deployment, and implementation of the unit's fire safety work plan and measures.
Third, a fire inspection and fire inspection system should be established to determine the personnel, content, location and frequency of inspections and inspections.
Fourth, regular fire safety publicity and training should be conducted through various forms.
Fifth, an evacuation facility management system shall be established. The responsible departments and responsible persons for the management of fire safety evacuation facilities shall be specified, and the requirements for regular maintenance and inspection shall be specified to ensure the management requirements of the safety evacuation facilities.
6. A fire-fighting facilities management system shall be established. The contents shall specify the responsible departments and responsible persons of fire-fighting facilities management, the inspection contents and requirements of fire-fighting facilities, and the requirements for regular maintenance of fire-fighting facilities.
Seventh, a system for rectification of fire hazards should be established to clarify the responsible departments for fire hazard correction, the responsible persons, the time limit for rectification, and the source of funding required.
VIII. A system for the management of electricity fire safety should be established, and the responsible department and responsible person for fire safety management should be specified.
IX. The fire and fire safety management system should be established. The responsibility department and responsible person who use fire and fire management should be clearly defined. The scope, procedures, and requirements for the approval of fire and hot work, as well as the qualification and duties of the electric welder Requirements and other content.
X. A flammable and explosive chemical management system should be established to clarify the responsible departments and responsible persons for the management of inflammable and explosive chemicals.
XI. A management system for key locations for fire safety should be established to determine the key locations for fire safety, and the responsible departments and responsible persons for fire safety management should be defined.
XII. A firefighting file management system shall be established. The contents shall specify the responsible departments and responsible persons of firefighting records management, and the requirements for the production, use, updating, and destruction of firefighting files.
XIII. A targeted fire extinguishing and emergency evacuation plan shall be established and fire drills shall be conducted.
14. After the fire broke out, immediately start the fire extinguishing and emergency evacuation plan, evacuate all the people in the building, implement the initial fire suppression, and report the fire. Fire sites should be protected, fire accident investigations should be conducted, lessons learned should be summarized, and fire safety management should be improved.
2. Fire safety regular meeting system
First, fire safety routines should be held at least once a month. The main contents of the meeting should be based on the research, deployment, and implementation of fire safety work plans and measures for this site. If major issues involving fire safety are concerned, thematic meetings should be organized at any time.
2. The fire safety case shall be chaired by the person responsible for fire safety. The person concerned shall participate and shall form a meeting minutes or a resolution to issue the relevant department and file it.
3. The agenda of the meeting mainly includes hearing the cancellation of anti-safety management personnel on fire safety, researching and analyzing the fire safety situation of the unit, and proposing solutions to relevant key and difficult issues, and arranging the next phase of fire safety work.
IV. Minutes or resolutions of special meetings held on major issues concerning fire safety shall be submitted to the local public security fire control department, and specific solutions and specific implementation measures shall be proposed.
V. If there is a fire accident in this unit, a special meeting should be held after the accident to analyze, find the cause of the accident, sum up the lesson of the accident, formulate rectification measures, and further implement the fire safety management responsibility to prevent accidents from happening again.
3, fire inspection system
First, the fire inspection should determine the personnel, content, location and frequency of inspections, and conduct fire inspections in a timely manner.
Second, fire inspections should be completed in the "daily fire inspection (night inspection) Record Form", inspection personnel should sign the record. During the patrol inspection, the fire hazards that could be rectified on the spot were found. Fill out the “Unit Fire Hidden Trouble Correction Notice†and eliminate the hidden trouble. If it cannot be eliminated on the spot, fill out the “Unit Fire Hidden Period Remedy Deadline Notice†and promptly report to the supervisor’s person in charge and Fire patrol (night inspection) record form record archive.
Third, daily fire inspections should be conducted, combined with the actual organization of night fire inspections. Boarding schools should organize daily fire inspections at night, not less than two times.
Fourth, fire inspections should include the following:
1. Use fire and electricity for violations;
2. Is the safety exit and evacuation channel unimpeded and whether it is locked or not; the safety evacuation indicator and emergency lighting are in good condition;
3. Is the normally closed fire door closed or is it stacked under the fire shutter?
4. Whether the firefighting facilities and equipment are in place, complete and effective. Is the fire safety sign intact and clear;
5. The personnel in the key positions of fire safety;
6. Other fire safety situations.
4, fire inspection systemFirst, fire prevention inspections should be carried out regularly. Each post should be filled once a day. Fill in the “Daily Fire Inspection (night inspection) Record Formâ€. Each department should fill out the weekly “Fire Inspection Status Record Form†and the unit should Once, fill in the “Monthly Fire Inspection Status Record Form†and check the construction firefighting facility once every quarter. Fill in the “Functional Inspection Record Form for Building Fire Fighting Facilitiesâ€.
Second, the inspection found that the fire hazards can be rectified on the spot, fill out the "unit fire hazard correction notice on the spot" and eliminate hidden dangers; can not be eliminated on the spot, fill out the "unit fire deadline deadline correction notice" and timely report to the person in charge, and records Archive.
Third, the fire inspection should include the following:
1 , fire truck access, fire water;
2 , safe evacuation passages, stairs, safety exits and evacuation signs, emergency lighting;
3. The setting of fire safety signs;
4 , fire extinguishing equipment configuration and its good condition;
5 , the construction of fire facilities operation;
6. Duty status of fire control room, operation of fire control equipment and related records;
7. Whether there is any illegal situation with fire or electricity;
8. The management of key parts of fire safety;
9. The implementation of fire inspections and their records;
10. The rectification of fire hazards and the implementation of preventive measures;
11. The implementation of fire prevention, explosion protection and lightning protection measures for flammable and explosive dangerous goods;
12. Blocking of key fireproof partitions such as floors, firewalls, and shaft holes;
13. The knowledge of fire fighting knowledge of key fire safety personnel and other employees.
It is recommended to use fire-fighting information software for fire inspection.
5, fire prevention education and training system
First, carry out regular fire safety publicity and training through various forms. The fire safety education and training is organized by the fire safety manager. According to the characteristics of different seasons and holidays, a variety of fire accident cases are combined. Fire prevention is promoted in various forms such as posting pictures, fire publications, videos, networks, and holding firefighting cultural activities. General knowledge such as firefighting, emergency firefighting, and emergency escape have enabled teachers and students to raise fire safety awareness and prevent self-rescue.
2. Organize centralized fire training for teaching staff at least once every six months, and deal with the fire training before the new employees or key positions, special types of workers, etc., related to the employees, and take the examination after the training. The results are unqualified or not. Employees who have undergone fire safety education and training may not be employed.
Third, firefighting training should include the following:
1. Fire regulations, fire safety management systems, and operating procedures to ensure fire safety;
2. The fire risk and fire prevention measures of the unit and the post;
3 , the performance of building fire fighting facilities, fire extinguishing equipment, using methods and operating procedures;
4. The knowledge and skills of reporting a fire, fighting an initial fire, emergency evacuation, and self-rescue escape;
5. The safety evacuation route of the site, the procedures and methods for guiding the evacuation of the personnel, etc.;
6 , fire extinguishing and emergency evacuation plan content, operating procedures.
Fourth, conduct popularization and enlightenment education for students on fire prevention knowledge, organize visits to local fire stations, and participate in firefighting summer camps and other activities.
V. Firefighting propaganda Fill out “Firefighting Publicity Recordâ€; Firefighting Training Fill out “Fire Safety Education, Training Record†and “Fire Safety Training Qualified Registration Form†and file it.
6. Safe Evacuation Facilities Management System
First, define the responsible departments and responsible persons for the management of fire safety evacuation facilities, the requirements for regular maintenance and inspection, and ensure the management requirements for safety evacuation facilities.
Second, safety evacuation facility management should meet the following requirements:
1. Ensure that the evacuation passages and safety exits are unblocked and that occupation and blocking of evacuation passages and stairwells are prohibited;
2. Doors for evacuating exits and safety exits during use should not be locked;
3. The doors of closed stairwells and smokeproof stairwells shall be in good condition, and the doors shall be marked with correct opening and closing status to ensure their normal use;
4. Normally closed fire doors should always be kept closed;
5. Fire doors that need to be kept open constantly should ensure that they can be automatically closed in case of fire; automatic and manual closing devices should be effective and effective;
6. The evacuation gates that normally need to control personnel access or have access control systems should have reliable measures to ensure the evacuation of people during fires;
7. Safety exits and evacuation doors must not be provided with thresholds and other obstacles that affect evacuation, and steps should not be set within 1.4m .
8. The fire emergency lighting and safety evacuation signs shall be sound and effective, and they shall be repaired and replaced in time if any damage occurs.
9. Fire safety signs should be intact and clear and should not be blocked;
10. Safe exits and public evacuation walkways should not be equipped with fences or rolling shutters;
11. The windows, balconies and other parts shall not be provided with barriers that may affect escape and fire fighting and rescue. If they must be set up, there shall be devices that can be easily opened from the inside;
12. The safety evacuation instruction map shall be set up in the obvious position of each floor, and the evacuation route, safety exit, location of personnel and necessary written instructions shall be marked on the instruction map;
Third, the inspection of safety evacuation facilities should be completed and archived "Safety evacuation facility inspection records."
7, fire facilities, equipment management system
1. The fire-fighting facilities and equipment management shall specify the responsible departments and responsible persons, the inspection contents and requirements of fire-fighting facilities, and the requirements for regular maintenance of fire-fighting facilities.
Second, the management of fire facilities should meet the following requirements:
1 , Fire hydrants should have obvious signs;
2 , indoor fire hydrant box should not be locked, the equipment inside the box should be complete, intact;
3 , outdoor fire hydrant should not be buried pressure, circle occupation; away from the outdoor fire hydrant, pump adapter within 2.0m shall not be set to affect its normal use of obstacles;
4. It must not affect the normal use of fire-fighting doors, fire shutters, indoor fire hydrants, fire extinguishing agent nozzles, mechanical exhaust and air outlets, natural exhaust windows, fire detectors, manual fire alarm buttons, and sound and light alarm devices. ;
5. Ensure that fire-fighting facilities and fire-fighting power supply are always in normal operation; when maintenance is required, corresponding measures shall be taken; after the completion of maintenance, the normal operation shall be resumed immediately;
6. Regularly inspect and inspect fire-fighting facilities in accordance with relevant standards, make records, and file them for future reference;
7. Automatic firefighting facilities shall, in accordance with relevant regulations, entrust an organization with relevant qualifications to carry out comprehensive inspections and tests every year, issue inspection reports, and send them to the local public security and fire control agencies for record.
8. Significant firefighting facilities, equipment, exits and other fire safety signs shall be set up in the collective dormitory.
Third, the fire control room should ensure that its environment meets the requirements of normal operation of equipment
4. The fire control room shall ensure that its environment satisfies the normal operation requirements of the equipment, set up the layout plan of the fire protection facilities, store the complete design, construction and acceptance data of the fire protection facilities, and the fire prevention and emergency evacuation plan.
V. Firefighting facilities and equipment inspections shall be respectively filled out with “Functional Inspection Record Forms for Building Fire Fighting Facilities†and “Safety Evacuation Facilities Inspection Recordsâ€.
8, fire hazard correction system
1. All kinds of potential unsafe factors caused by violation or non-compliance with fire regulations should be identified as fire hazards.
2. During inspections and inspections, fire hazards that can be rectified on the spot are found. The “Unit Fire Hidden Trouble Correction Notice†should be filled in immediately and corrected on the spot; if it cannot be corrected immediately, fill in the “Unit Fire Hidden Difficulty Period Rectification Notice†and step by step. Report the fire safety manager to take measures for rectification.
3. The fire safety manager or department responsible for fire safety shall organize the identification of the reported fire hazards, clarify the responsible departments for fire hazard correction, the responsible persons, the time limit for rectification, and the source of funding required.
Fourth, during the rectification of fire hazards, appropriate measures should be taken to ensure safety.
5. The fire safety manager or department responsible for fire safety shall review and confirm the completion of the correction of fire hazards, and fill in the "Review and Revise Checklist for Unit Fire Hazard Remediation".
6. Fire hazards and major fire hazards that are ordered by public security fire control agencies to be rectified within a time limit shall be corrected within the prescribed time limit, and the fire hazard correction letter shall be sent to public security fire control agencies.
7. If major fire hazards cannot be rectified immediately, the dangerous parts shall be rectified and stopped.
VIII. For major fire hazards involving urban planning and layout that cannot be resolved by itself, solutions should be proposed and reported to their superior authorities or the local people's government in a timely manner.
9, electricity fire safety management system
1. The responsible department and responsible person of the fire safety management shall be specified in the fire safety management of electricity use;
Second, the procurement of electrical and thermal equipment, should use qualified products, and should meet the requirements of the relevant safety standards;
Third, the laying of electrical lines, installation and maintenance of electrical equipment should be performed by qualified electricians.
Fourth, do not arbitrarily indiscriminately wire, unauthorized addition of electricity equipment;
5. The spacing between electrical equipment and flammables should be kept at a distance of 0.5m or more;
6. The electrical circuits and equipment shall be inspected and tested regularly, and overloaded operation is strictly prohibited;
7. Collective quarters shall be equipped with electricity overload protection devices.
10. Fire safety management system
First, use the fire safety management should be clearly responsible for the management of the responsible departments and responsible persons, the use of fire, moving fire approval scope, procedures and requirements, as well as the qualifications of electrical welders and their responsibilities requirements.
Second, the use of fire, fire safety management should meet the following requirements:
1. The fire-proof construction area and other areas should be separated by fire.
2. Before the open fire operation such as electric welding, the departments and personnel implementing the hot work shall fill out the “Approval Form for Temporary Use of Fires and Electricity for Work Units†to handle the fire approval procedures, remove flammable combustibles, configure fire fighting equipment, and implement the on-site guardians. Safety measures, after confirming that there is no danger of fire or explosion, the construction of fire can be started.
3. Should not use open fire lighting or heating, if special circumstances need to have special care.
4. Fire and heat insulation measures shall be taken between heating facilities such as flue gas and combustibles.
5. The kitchen flue should be cleaned at least once every quarter.
6. The fuel and gas pipelines should be inspected, tested and maintained.
7. It is forbidden to use open flames such as candles and electric stoves in the dormitory. When it is necessary to use the stove for heating, special personnel should be responsible.
11. Flammable and Explosive Chemicals Management System
1. The types, quantities, storage locations, etc. of flammable and explosive chemical dangerous goods purchased by each department of a unit shall be filled out with the “Table of Filings for Flammable and Explosive Chemicals†and written in advance with the security department in writing.
Second, all types of flammable and explosive chemical dangerous goods shall be packaged, transported and stored separately according to their different properties, and mixed packing, mixed transportation and mixed storage shall be prohibited.
Third, flammable and explosive chemical dangerous goods must be kept by special personnel, fixed-point storage.
Fourth, the storage warehouse should meet the requirements of fire protection, smoking inside the warehouse is strictly prohibited. When using, it should strictly fulfill the picking registration system and fill out the “Registration Form for Recovering Flammable and Explosive Chemicalsâ€. Unrelated personnel are strictly prohibited from entering the warehouse. There should be clear rules and regulations, warnings and slogans in the warehouse.
5. The storage of flammable and explosive chemical dangerous goods used by the laboratory shall not exceed the amount used on the day, and personal use of the classroom shall be limited. After the experiment, the laboratory shall be fully inspected to ensure safety, and the remaining flammable and explosive chemical dangerous goods shall be used for recovery. Residues and residual liquids shall not be dumped at will and shall be disposed of safely.
Sixth, the use of departments and individuals must be strictly responsible and operating procedures, the use of safety precautions must be taken to prevent disaster accidents and personal injury accidents.
VII. The use and storage of flammable and explosive chemical dangerous articles that are not in accordance with regulations shall be handled in accordance with the circumstances, and if an accident is caused, the parties concerned shall be held accountable.
12. Fire safety key location management system
1. Classrooms, transformer rooms, boiler rooms, canteen operation rooms, air-conditioning rooms, libraries, flammable goods warehouses, fire control rooms, laboratories, dormitories, etc. should be identified as key parts of fire safety, and the responsibilities for fire safety management should be clarified. Department and responsible person.
Second, should be equipped with appropriate fire extinguishing equipment, equipment and personal protective equipment according to actual needs.
Third, it is necessary to formulate and improve the accident emergency operation procedures.
Fourth, should be included in the scope of fire inspections, as the focus of regular inspections.
13. Fire Control File Management System
1. Defining the requirements of the responsible departments and responsible persons of the firefighting records management, the production, use, updating and destruction of firefighting files.
Second, the fire file management should meet the following requirements:
1. Establish paper firefighting files in accordance with relevant regulations, and establish electronic files at the same time;
2. The firefighting archives shall include the basic conditions of fire safety, fire safety management, fire prevention and emergency evacuation plans;
3. The contents of firefighting archives should be detailed, comprehensively reflect the basic conditions of firefighting work, and must be accompanied with necessary drawings and diagrams;
4. Fire files should be managed by special personnel and bound according to file management requirements.
Third, the basic situation of fire safety should include the following:
1. Basic overview and key fire safety situations;
2. Permitting documents and relevant documents for fire safety inspection before the construction fire protection design audit, fire inspection and acceptance, as well as the use of the site or the opening of the business;
3. Fire protection organizations and fire safety managers at all levels;
4. Fire safety management system and operating procedures to ensure fire safety;
5. Configuration of fire-fighting facilities and fire-fighting equipment;
6. Compulsory fire brigade personnel and their fire fighting equipment;
7. Basic information of fire safety managers, automatic fire protection facility operators, electric welders, electricians, and flammable and explosive chemical operators;
8. New certification materials for fire protection products and fire protection materials.
Fourth, the fire safety management situation should include the following:
1. A summary or decision of a fire safety meeting;
2. Various legal documents filled out by public security fire control agencies;
3. Periodic inspection records of firefighting facilities, reports of comprehensive inspection and test of automatic firefighting facilities, and maintenance records;
4. Fire hazards, major fire hazards, and records of their rectification;
5. Fire inspection and inspection records;
6. Records related to gas and electrical equipment testing;
7. Fire safety training records;
8. Fire drill and emergency evacuation plan drill record;
9. Record of fire conditions;
10. Record of firefighting rewards and punishments.
14. Preparation and drill system for fire fighting and emergency evacuation plans
1. The unit shall formulate targeted fire prevention and emergency evacuation plans in light of the concentration of personnel, the high risk of fire and the actual situation of key locations.
Second, the plan should include the following:
(1) The person in charge who clearly identifies the fire scene communication, fire fighting, evacuation, rescue, and defense tasks. Large-scale personnel-intensive places should be led by specialized agencies and set up various functional groups. And clearly responsible person, the composition of personnel and their responsibilities;
(b) fire management procedures;
(3) the organizational procedures and measures for emergency evacuation;
(4) Procedures and measures for fighting an initial fire;
(5) Organization and scheduling procedures and safeguards for communication, security, and personnel rescue.
Third, the organization
(1) The person responsible for fire safety or the fire safety manager is responsible for the command responsibilities of the public security fire brigade before he arrives at the fire scene, and organizes the work of fire extinguishing and emergency evacuation. Larger units can set up fire accident emergency command agencies.
(2) All responsibilities for fire extinguishing and emergency evacuation shall be borne by the on-duty fire safety manager, department heads, fire control room staff, security personnel, and obligatory fire brigade. Larger units may set up functional groups, which consist of fire safety managers, department heads, fire control room staff on duty, security personnel, voluntary fire brigades, and other employees in post. The main responsibilities are as follows:
1. Communication and communication: Responsible for communication and liaison with fire safety managers and local public security fire control agencies;
2. Extinguishing fires: In the event of fire, use fire-fighting equipment and facilities for fire suppression on the spot;
3. Evacuation: Responsible for guiding personnel to properly evacuate and escape;
4. Ambulance: assisting in rescue and escorting injured persons;
5. Defend: Prevent persons who have nothing to do with the place from entering the scene, protect the fire scene, and assist public security fire control agencies in conducting fire investigations;
6. Logistics: Responsible for the supply of emergency supplies, equipment and logistics.
Fourth, plan implementation process
When the fire is confirmed, the fire extinguishing and emergency evacuation plan shall be started immediately and the following work shall be carried out at the same time:
(1) To report fire to the public security fire control agencies;
(2) the corresponding duties of the on-duty personnel in executing the preplan;
(c) Organize and guide personnel to evacuate and rescue trapped persons;
(4) The use of fire hydrants and other fire-fighting equipment and facilities to put an end to the initial fire;
(v) Send someone to meet fire engines to reach the fire scene;
(6) Protect the fire scene and maintain the order at the scene.
V. Propaganda and improvement of the plan
Employees should be regularly familiarized with fire prevention and emergency evacuation plans, and through the plan drills, gradually revised and improved.
6. Fire drill
(1) To inspect the level of familiarity with the contents and responsibilities of fire prevention and emergency evacuation plans by the responsible persons for fire safety at all levels, various functional groups and relevant personnel.
(b) The safety evacuation of inspectors, initial fire suppression, and the use of fire fighting facilities.
(3) To examine the capabilities of the organization in the organization, command, communications and rescue in the event of an emergency.
(4) To test the practicality and operability of the emergency fire evacuation plan.
(v) It should be organized at least once a year.
(six) should choose personnel concentration, fire risk and key positions as the goal of fire drills, according to the actual situation, determine the fire simulation form.
(7) The fire drill program may report to the local public security fire control agency for its business guidance.
(8) Before the fire drill, the teaching staff and students of the school shall be informed to actively participate in the fire drill; during the fire drill, the sign of “is undergoing fire drill†shall be set up at a conspicuous place such as the entrance of the building to make an announcement.
(9) Fire drills shall be implemented in accordance with fire prevention and emergency evacuation plans.
(10) Control measures for fire source and smoke should be implemented during simulated fire drills to prevent injury to personnel.
(11) After the drill, the fire control facilities should be restored to normal operation status, and the “Drilling and emergency evacuation plan drill record†should be filled out and archived in a timely manner.
15. Fire accident disposal system
First, after confirming that a fire has occurred, fire prevention and emergency evacuation plans should be started immediately to inform all personnel in the building to evacuate immediately, implement initial fire fighting, and report fire.
2. After the fire broke out, the fire scene should be protected. The range of warning prescribed by the public security fire control agency is the protection scope of the fire scene; it is not yet scheduled, and the fire overfire range and the parts related to the fire should be designated as the fire protection scope.
3. Without the permission of the public security fire control agency, no one shall enter the protection scope of the fire scene without permission and shall not arbitrarily move any object in the fire scene.
4. No person may clean up the fire scene without the consent of the public security fire control agency.
Fifth, the accident investigation should be accepted, and the fire accident situation should be provided truthfully to find relevant personnel and assist in the fire investigation.
Sixth, arrangements should be made for fire casualties and their relatives and aftermath matters.
7. After the completion of the fire investigation, the cause of the accident should be analyzed in a timely manner, and lessons learned should be summarized. Fire safety management should be improved in a timely manner to prevent recurrence of fire accidents and to record accidents in fire prevention files.
16. Safety Management System for Gas and Electric Equipment
I. Responsibility departments and responsible persons who should clearly manage the management of gas and electrical equipment
Second, the procurement of electrical and thermal equipment, should use qualified products, and should meet the requirements of the relevant safety standards;
3. Gas pipelines, laying of electrical lines, installation and maintenance of electrical equipment should be performed by personnel with professional qualifications;
Fourth, do not arbitrarily change the gas pipeline, not random wire, unauthorized addition of electricity equipment;
5. The distance between fuel gas and electrical equipment and combustibles should be kept more than 0.5m ;
6. The gas pipelines, equipment, electrical lines, and equipment shall be regularly inspected and inspected. It is forbidden to overload the electrical equipment;
17. Fire safety work evaluation reward and punishment system
1. The unit shall incorporate the fire safety work into the contents of internal inspection, assessment and appraisal.
2. The departments, individuals, and units that have achieved outstanding results in fire safety work shall be commended and awarded.
3. The act of failing to perform fire safety duties in accordance with the law or violating the unit's fire safety system shall be subject to administrative disciplinary measures or other treatment in accordance with relevant regulations.
4. Where violations of fire laws and regulations, and administrative penalties should be imposed according to law, punishment shall be imposed in accordance with relevant laws and regulations; if a crime is constituted, criminal responsibility shall be investigated according to law.
18. Fire Control Room Duty System
1. The unit should establish a duty control system for fire control rooms. The duties of the on-duty personnel should be clearly defined. The 24- hour staff should be on duty every day. The number of people on duty should not be less than 2 . Duty officers in the fire control room shall be certified by the fire department after passing the training.
Second, the on-duty personnel are handing over classes on time, and do a good job in the transfer procedures of duty records, fire inspections, handling of found problems, and handling of accidents. There is no handover procedure, and on-duty personnel are not allowed to leave the post without permission.
3. When it is found that there is a problem with the operation of a fire-fighting facility, measures should be taken promptly and report to the responsible person in charge.
Fourth, non-work needs, may not use the control center call, non-fire control center staff on duty are prohibited from entering the duty room.
5. When a fire is discovered, the fire emergency emergency evacuation plan shall be promptly handled and the 119 fire alarm shall be called to notify the public security fire department and report to the department head.
6. Fill in the "Dongguan fire control room records" should be complete, clear and well-kept.
19, fire watch system
1. The unit shall clearly define the responsibilities of the on-duty personnel, formulate procedures and requirements for on-duty 24h shifts and shifts, and procedures and requirements for fire inspections.
2. On-duty personnel at all levels perform their duties strictly. Duty leaders are responsible for inspecting and supervising on-duty personnel to carry out fire inspections. On-duty personnel are responsible for conducting fire inspections of this unit.
Third, fire inspections should be carefully recorded, found that fire safety problems should be taken promptly and reported step by step. In the event of a fire, they should be promptly dealt with in accordance with the fire extinguishing and emergency evacuation plan. If necessary, a 119 fire alarm call should be made to report the fire to the 119 command center and report to the head of the department head.
4. On-duty personnel shall be handed over on time in classes, and the procedures for the handover of records of handover classes and fire inspections, problem disposal, and accident handling shall be completed. There is no handover procedure, and on-duty personnel are not allowed to leave the post without permission.
5. It is forbidden to take off posts, drink alcohol, and engage in various recreational activities during the shift. It is forbidden to sleep.
20. Fire management organization (compulsory fire brigade) management system
1. The firefighting organization ( competent fire brigade ) shall conduct business study and fire-fighting skill training under the leadership of the centralized management department of firefighting work, and all technical assessments shall meet the specified targets.
Second, it is necessary to combine the inspection and maintenance of fire-fighting facilities, equipment, and equipment, and carry out round-robin training for each compulsory firefighter in a planned manner so that everyone has practical skills.
3. Perform drills at least once a year in accordance with the fire prevention and emergency evacuation plan, and Sandpaper,Sand Paper,Sanding Pads,Wet And Dry Sandpaper Foshan SUMEITE Grinding Technology Co.,Ltd , https://www.aedetail.com