How to maintain the price of heat preservation water tank

1. The air source heat pump water heater is a highly automated equipment. When it is used, the status of the unit is periodically checked. If the unit can be maintained and maintained for a long period of time, the operational reliability and service life of the unit will be unexpectedly improved.
2. The water filter installed outside the machine should be cleaned regularly to ensure the water quality in the system is clean, so as to avoid damage to the main unit caused by dirty filter plugging.
3. The user should pay attention when using and maintaining the heat pump unit: All the safety protection devices in the unit are set before leaving the factory. Do not disassemble or adjust them by yourself.
4. Air source heat pump water heaters often check the unit's power supply and electrical system wiring is solid, whether there are abnormal electrical components, if any, should be promptly repaired and replaced.
5. Regularly inspect the replenishment of the water system, the safety valve of the tank, the liquid level controller, and the exhaust device for proper operation so as to prevent air from entering the system and reduce the amount of water circulation, thereby affecting the heating capacity of the unit and the reliability of the unit operation.
6. Check whether the pump and waterway valve are working properly and whether the water pipeline and water pipe joints are leaking.
7. The unit should be kept clean and dry and well ventilated. Clean the air side heat exchanger every year to maintain a good heat transfer effect.
8. Regularly inspect the working conditions of the various components of the unit, check whether the pipe joints and inflation valves in the machine are dirty, and ensure that no refrigerant is leaked from the unit.
9. Do not stack debris around the unit so as not to block the air inlet and outlet. The unit should be kept clean and dry with good ventilation.
10. If the downtime is long, the water in the piping of the unit should be let off, and the power should be cut off and the protective cover should be put on. When running again, check the system before turning on the machine.
11. When the actual water outlet temperature of the air source heat pump water heater is different from the value displayed on the unit control panel, check whether the temperature sensing device is in good contact.
12. If the unit fails and the user cannot solve it, please report it to the after-sales service department promptly and inform the fault code to promptly send someone to repair.
13. The main condenser cleaning, we recommend using a 50 °C -60 °C, 15% concentration of hot phosphoric acid solution every two years to clean the condenser, start the host comes with a circulating pump cleaning 3 hours, and finally washed with tap water 3 times. Take over when cleaning. Do not use a caustic cleaning solution to clean the condenser.
14. Water tanks need to be cleaned after use for a period of time (usually 3 months, depending on the local water quality).