Channel gates such as wing gates and swing gates are very common gate gates. They are used in a wide range of occasions and are used at a high frequency. Wing gates, swing gates and other channel gates, if carefully maintained, generally do not cause major problems. However, a small probability event does not mean that it will not occur. Maintenance personnel know more about some practical troubleshooting methods, which will bring a lot of convenience to daily maintenance.

1. After swiping the wing gate, swing gate and other channel gates, the swing gate will not open the door, there will be no response, or it will not automatically open after the power is turned off. Check again to see if the open signal line has dropped. Check the open signal on the motherboard Whether the indicator light has received the on signal.
2. After swiping the card, the gate is opened, but the gate is not closed. In this case, the middle anti-pinch infrared is not right. Before fixing the chassis, you must make sure that the infrared is aligned properly to open and close the door normally. If the infrared is not properly aligned, it will give an alarm after power on. After swiping, please follow the direction arrow to exercise.

3. After the channel gate is swiped, one is opened and the other is not opened. Check again if the sync cable is connected. After the connection is ensured, whether the main board which cannot be opened has received the open signal, if not, recheck whether the wiring is dropped and whether the plug on the main board is inserted properly.
4. The working states of the direction indication of channel gates such as wing gates, swing gates, etc. are respectively: the green arrow points to the left, the right, or the red cross. If the direction indication does not respond, or the indicated direction is incorrect. You can switch to another test and try it with a good pair. Check the wiring again.